1) U INSTALLATION FOR VERTICAL MOVEMENTS

L = 4R + 0,5C
L 1 = 1,43R + 0,5C
L 2 = 1,43R

 

2) U INSTALLATION FOR HORIZONTAL MOVEMENTS

L = 4R + 1,57C
L 1 = 1,43R + 0,785C
L 2 = 1,43R + 0,5C

 

3) C INSTALLATION FOR HORIZONTAL MOVEMENTS

L = 4R + 0,5C
L 1 = 1,43R + 0,5C
L 2 = 1,43R

 

4) U INSTALLATION FOR COMBINED MOVEMENTS

L = 4R + 1,57C + 0,5C2
L 1 = 1,43R + 0,785C1 + 0,5C2
L 2 = 1,43R + 0,5C1


L = leght of flexible portion
R = installation bending radius
C = total movement